Fire rated metal door frames are primarily designed to suit E-Core Residential Mini and Commercial Maxi fire doors . E-Core fire doors are available for a variety of applications. The resulting range of door leaf and door frame combinations allow choices in different levels of fire ratings, noise and smoke reduction while maintaining strength and durability for a wide range of wall systems.
Features
Mini fire doors have 1.1 mm thick zincanneal mild steel door frames
Maxi fire doors have 1.4 mm thick zincanneal mild steel door frames
Fast Fix Bracket (in Masonry Frame) allows for installation in plasterboard partition walls using stud fixing straps.
Frames are to be backfilled with mortar, grout, plaster, plasterboard or concrete unless otherwise specified.
All door frames to have 25 mm wide door stop but there are restricted approvals for 15 mm wide door frame stops
Currently fire rated door frames are available for the following wall types:
- Steel or timber stud plasterboard partition walls
- Brick, block or concrete masonry walls
- Rapidwall wall systems
- CSR Hebel wall systems
The Trafalgar Tru Seal metal door frames are also approved on Maxi fire doors for fire ratings up to 4 hours.
All fire rated door frames meet the following standards:
Australian Standard AS 1530 Part 4
Australian & New Zealand Standard AS/NZS 1905 Part 1
Building Code of Australia
Associated Standards:
Australian Standard AS 1191 - Acoustic-Method for laboratory measurement of airborne sound transmission loss of building partitions
Australian/New Zealand Standard AS/NZS 1276 Part 1 - Acoustics-Rating of sound insulation in buildings and of building elements
British Standard BS 476 Fire tests on building materials and structures Part 20 Methods for determination of the fire resistance of elements of construction (general principles)
British Standard BS 476 Fire tests on building materials and structures Part 22 Methods for determination of the fire resistance of non-load bearing elements of construction
New Zealand Standard NZ 4232- Performance criteria for fire resistance closures (Cyclic Endurance Test: 5,000 Cycles)
Singapore Standard SS 332- Specification for fire doors (Cyclic Endurance Test: 100,000 Cycles)
ANSI/UL 10B- Fire tests of door assemblies and CAN4-S104-M80- Standard method of fire tests of door assemblies (Subject to Fire and Hose Stream Test
Trade Connect members receive
an extra 5% discount!! - click
here
Sorry - There are no products that match your search term, or the product is not available in your state
This may be because:
You have mispelt your search term
You are using too many words in your search
There are no products available in this category
This product is not available in your state
We suggest you try the following:
Review the spelling of your search term
Shorten your search term (try using a single word)
Browse the products available in your state by using the Product Categories menu on the left